Rib Intrusion

Fig. 6: Nodes for extracting Rib intrusions
The rib intrusions can be measured by determining the distance between nodes. The nodes shown in Fig.6 are coincident at the beginning of the simulation. An increase in the distance between the nodes gives the rib intrusion of the model.
| Item | Node ID |
Label |
Component |
|---|---|---|---|
| Upper rib intrusion |
10061 10115 |
intrusion upper rib 1 intrusion upper rib 2 |
relative displacement relative displacement |
| Middle rib intrusion | 10065 10116 |
intrusion middle rib 1 intrusion middle rib 2 |
relative displacement relative displacement |
| Lower rib intrusion | 10070 10117 |
intrusion lower rib 1 intrusion lower rib 2 |
relative displacement relative displacement |
Alternatively, the elongation of a spring can be used to determine the rib intrusion. The spring elements are listed in the table below. The springs are located in the piston bearing system.
We do recommend to use spring elements to determine the Rib intrusion.
| Item | Element ID |
Component |
|---|---|---|
| Upper rib intrusion |
Spring 10500 |
change in length |
| Middle rib intrusion | Spring 10501 | change in length |
| Lower rib intrusion | Spring 10502 | change in length |